ISwitchV2SwitchStep Method

Returns the step size that this device supports (the difference between successive values of the device).

Definition

Namespace: ASCOM.Common.DeviceInterfaces
Assembly: ASCOM.Common (in ASCOM.Common.dll) Version: 2.2.1+77356f79b05b579f6d860a4edd5934fda9fe29e4
C#
double SwitchStep(
	short id
)

Parameters

id  Int16
The device number (0 to MaxSwitch - 1)

Return Value

Double
The step size for this device.

Remarks

Must be implemented, must not throw NotImplementedException.

SwitchStep, MinSwitchValue and MaxSwitchValue can be used to determine the way the device is controlled and/or displayed, for example by setting the number of decimal places or number of states for a display.

SwitchStep(Int16) must be greater than zero and the number of steps can be calculated as: ((MaxSwitchValue(Int16) - MinSwitchValue(Int16)) / SwitchStep(Int16)) + 1.

The switch range (MaxSwitchValue(Int16) - MinSwitchValue(Int16)) must be an exact multiple of SwitchStep(Int16).

If a two state device cannot report its state, SwitchStep(Int16) should return the value 1.0.

Devices are numbered from 0 to MaxSwitch - 1.

This is a Version 2 method.

Exceptions

InvalidValueExceptionIf id is outside the range 0 to MaxSwitch - 1
NotConnectedExceptionWhen Connected is False.
DriverExceptionAn error occurred that is not described by one of the more specific ASCOM exceptions. Include sufficient detail in the message text to enable the issue to be accurately diagnosed by someone other than yourself.