ISwitchV2SwitchStep Method |
Namespace: ASCOM.DeviceInterface
| Exception | Condition |
|---|---|
| InvalidValueException | If id is outside the range 0 to MaxSwitch - 1 |
| NotConnectedException | If the device is not connected |
| DriverException | An error occurred that is not described by one of the more specific ASCOM exceptions. Include sufficient detail in the message text to enable the issue to be accurately diagnosed by someone other than yourself. |
Must be implemented, must not throw MethodNotImplementedException.
SwitchStep, MinSwitchValue and MaxSwitchValue can be used to determine the way the device is controlled and/or displayed, for example by setting the number of decimal places or number of states for a display.
SwitchStep(Int16) must be greater than zero and the number of steps can be calculated as: ((MaxSwitchValue(Int16) - MinSwitchValue(Int16)) / SwitchStep(Int16)) + 1.
The switch range (MaxSwitchValue(Int16) - MinSwitchValue(Int16)) must be an exact multiple of SwitchStep(Int16).
If a two state device cannot report its state, SwitchStep(Int16) must return the value 1.0.
Devices are numbered from 0 to MaxSwitch - 1.