Click or drag to resize

ICoverCalibratorV1CalibratorOff Method

Turns the calibrator off if the device has calibration capability

Namespace:  ASCOM.DeviceInterface
Assembly:  ASCOM.DeviceInterfaces (in ASCOM.DeviceInterfaces.dll) Version: 3351c4f3fa64146a7efd5b51ed4591e32a0a5484
Syntax
void CalibratorOff()
Exceptions
ExceptionCondition
MethodNotImplementedExceptionWhen CalibratorState returns NotPresent.
NotConnectedExceptionIf the device is not connected.
DriverExceptionAn error occurred that is not described by one of the more specific ASCOM exceptions. Include sufficient detail in the message text to enable the issue to be accurately diagnosed by someone other than yourself.
Remarks

This is a mandatory method for a calibrator device.

If the calibrator requires time to safely stabilise after use, CalibratorState must return NotReady. When the calibrator is safely off CalibratorState must return Off.

For devices with both cover and calibrator capabilities, this method will return the CoverState to its status prior to calling CalibratorOn(Int32).

If an error condition arises while turning off the calibrator, CalibratorState must be set to Error rather than Unknown.

See Also